What’s the Difference Between Fire Exit Hardware & Panic Hardware?
Fire Exit Hardware
Essential elements for fire-rated exit doors: To prevent the spread of smoke and flames, it's always nececessary to install the fire exit devices on doors that have been specifically rated to withstand fire.
Meet UL 10C (fire rating) and ANSI/BHMA A156.3: These standards ensure the hardware can endure extreme conditions, such as high heat, and still function correctly during a fire emergency.
Panic Hardware
Focuses on emergency egress: Panic devices ensures that doors can be opened easily during an emergency, allowing for quick evacuation. However, these systems are not necessarily fire-rated.
Common in non-rated doors: Panic devices are typically used on doors that do not require a fire rating.
Camax Fire Exit Hardware Solutions
Choose from CE and UL-certified touch bar exit devices, cross bar exit devices, mortise locks and adaptable trims options for fire door protection.
Panic Exit Devices
Image | Type | Certification | Hand | Material | Lock Point | |
---|---|---|---|---|---|---|
CMP000 Series | ![]() |
Half or Full length of touch bar exit devices | ANSI/BHMA A156.3 grade 2; UL listed | Non-handed | Stainless steel, Steel | 1 or 2 |
CMP450 Series | ![]() |
Half length of touch bar exit device | ANSI/BHMA A156.3 grade 1; UL 10C, 3 hours fire rated | Non-handed | Stainless steel, Steel, Aluminum | 1, 2, 3 or 4 |
CMP466/463 | ![]() |
Concealed half length of touch bar exit device | (Pending) ANSI/BHMA A156.3 grade 1; UL 10C, 3 hours fire rated | Non-handed | Stainless steel, Steel, Aluminum | 1 or 2 |
CMP350 Series | ![]() |
Cross bar Exit Device | EN1125, category 3; EN1634-1, fire rated 2 hours | Handed | Stainless steel, Steel, Plastic | 1 or 2 |
CMP366 | ![]() |
Cross bar Exit Device | EN1125; EN1634-1, fire rated | Non-handed | Stainless steel, Steel, Plastic | 2 |
CMP500 Series | ![]() |
Cross bar Exit Device | EN1125; EN1634-1; EN12211, 6000Pa: CMP511 certificate | Non-handed | Stainless steel, Steel | 1, 2, 3 or 4 |
Mortise Locks for Panic Exit Devices
Image | Type | Compliance | Hand | Panic Function | |
---|---|---|---|---|---|
72-65PT | ![]() |
Exit Lock | EN12209; EN179 | Non-handed | Key action on latch bolt; Single throw dead bolt; Without strike plate. |
72-65PC | ![]() |
Classroom Lock | EN12209; EN179 | Key action on latch bolt; Two-piece follower; Without strike plate. | |
72-65DA | ![]() |
Exit Lock | Non-handed | Key to unlock; Without strike plate. | |
72-60/65TR | ![]() |
Exit Lock | EN12209; EN179; EN1125 | Non-handed | Key to unlock; Without strike plate. |
72-60/65TF | ![]() |
Automatic Deadbolt Locking Exit Lock | EN12209; EN179; EN1125 | Non-handed | Lock case seal, zinc plated; Bolt projection, one throw, 20mm |
35-92TR | ![]() |
Exit Lock | EN12209; EN179; EN1125 | Non-handed | Key to unlock; Without strike plate. |
Trims for Panic Exit Devices
Image | Type | Certification | Feature | Hand | Material | |
---|---|---|---|---|---|---|
CMPA004/004B/006 | ![]() |
Lever & Rose Trim | EN1634-1, fire rated | CMPA004/006: with fixed cross shape spindle; CMPA004B: with spindle housing adaptor | Non-handed | Stainless steel; Steel |
CMPA008/010 | ![]() |
Escutcheon Trim | EN1634-1, fire rated | Cylinder can be changed on site | Non-handed | Stainless steel; Steel |
CMPA012 | ![]() |
Escutcheon Lever Trim | EN1634, fire rated | For narrow stile doors, Function 008, key locks & unlocks handle; Free wheeling, clutch design | Non-handed | Stainless steel 304 |
CMPA401 | ![]() |
Escutcheon Trim | (Pending) UL 10C fire rated | Standard with ACY-28.6mm cylinder; SFIC cylinder is optional; Door thickness 44-50mm | Non-handed | Stainless steel; Steel |
CMPA410 | ![]() |
Escutcheon Trim | (Pending) UL fire rated | Standard with ACY-28.6mm cylinder; SFIC cylinder is optional; Door thickness 44-50mm | Non-handed | Stainless steel; Steel |
CMPA450 Series | ![]() |
Pull & Thumbpiece Trim, Wide Stile | Trim has through-bolts to the device chassis for more security and durability. It fits 1-3/4" (44mm) door standard. | Non-handed | Finish: US3, US4, US10, US10B, US26, US26B & US32D |
Camax Hardware FAQ for Fire Exit Devices
Find answers to common questions about fire exit devices and services
Q1. What safety certifications do Camax fire exit hardware products have?
Camax fire exit hardware, like fire exit push bar and cross bar, meets the most stringent international safety standards, including:
ANSI/BHMA Grade 1 for durability (300,000+ test cycles)
UL 10C fire ratings (60-90 minute protection)
CE EN 1125 for panic hardware in Europe
Fire door assembly certifications (tested with doors/frames)
Every product undergoes rigorous third-party testing to ensure compliance with building codes. Certificates are available upon request for specifiers and inspectors.
Q2. What installation support does Camax provide?
Camax Hardware ensures seamless installation of fire door panic hardware through:
Comprehensive Manuals: Professionally illustrated guides with step-by-step instructions, technical specifications, and safety protocols for all hardware models.
Dedicated Expert Support: Our certified technicians are available to provide: Custom configuration advice, Code compliance verification, Troubleshooting assistance
Simply contact Camax support team for detailed assistance.
Q3. Is it possible to integrate mortise locks with Camax panic hardware for enhanced security?
Absolutely. Our mortise exit devices combine emergency egress with superior locking, like:
The CMP455 push bar exit device pairs with ANSI A156.13 mortise locks (Grade 1)
The CMP505 crossbar exit device works with EN 12209 mortise locks (3-star security)
Custom configurations available for fire-rated doors up to 3 hours
These hybrid systems are ideal for banks, hospitals, and government buildings needing both safety and access control. Contact Camax Hardware for more mortise exit device solutions.
Q4. Where are Camax fire exit devices typically installed?
Our hardware is trusted in mission-critical environments worldwide:
Healthcare: Hospital stairwells (fire/smoke compartmentalization)
Education: School corridors with 90-minute fire ratings
Commercial: High-rise office building emergency exits
Hospitality: Hotel ballrooms with concealed vertical rod devices
Government: Courthouses with tamper-resistant crossbars
We help architects select the right solution for each door location and traffic pattern.
Contact Camax Hardware for Door Solutions
Specifying door and window hardware for your next project? Our expert team ensures seamless integration from design to installation.
Contact Camax Hardware for Door Solutions
Specifying door and window hardware for your next project? Our expert team ensures seamless integration from design to installation.